    理士蓄电池DJ2V系列单只终止放电电压为1.8V

    分享到:
    点击次数:519 更新时间:2021年07月21日10:50:18 打印此页 关闭


        理士蓄电池DJ2V100-3000AH充放电总体要求:由于理士蓄电池在存放过程中自放电等原因,投入运行前要做补充充电和一次容量试验。补充充电方式按产品使用说明书选择恒流充电法或者低压恒压充电法,待充电结束后进行一次容量试验,放电深度为95C1010小时率),放电期间注意蓄电池的温度不能有明显的升高,放电时每小时应测一次电压(单体及电池组)、放电电流、环境温度及蓄电池剩余容量,并做好详细记录,出现单节理士电池电压低于1.8V时立即停止放电。

    2V100AH.jpg

    Lishi battery DJ2V100-3000AH charge and discharge general requirements: due to Lishi battery in the storage process of self-discharge and other reasons, before putting into operation to do a supplementary charging and a capacity test. The supplementary charging method is to choose the constant current charging method or the low voltage constant voltage charging method according to the product instruction. A capacity test shall be carried out after the end of charging, and the discharge depth shall be 95%C10 (10-hour rate). During the discharge, pay attention to the temperature of the battery shall not increase significantly. When discharging, the voltage (monomer and battery pack), discharge current, ambient temperature and the remaining capacity of the battery should be measured once an hour, and make detailed records. When the voltage of the single joint battery is lower than 1.8V, the discharge should be stopped immediately.